Specifications
Air Cooled
※1 The temperature and humidity control range noted does not necessarily indicate the actual controllable range possible. The actual controllable temperature and humidity ranges will depend on the temperature and humidity of the intake air. (Vapor humidification is used in the humidity setting range of 65 ~ 75%.)
※2 When the air temperature and humidity is stable at the air intake. Noted accuracy is based on measurement by the internal controller at a single air outlet point.
※3 The noted external static pressure is when the controlled air is regulated at the outlet to produce the maximum rated processing air flow.
※4 Height includes outlet port.
※5 The HEPA filter box is shipped in a separate package from the main unit and must be installed on-site.
※6 The figure noted is when the equipment is operating at the highest level of humidification.
※7 Supply compressed air that has been cleaned through filter and/or other processing. The cleanliness of the compressed air supply should match the air cleanliness standard of the target area to which the controlled air will be supplied.
※8 Source voltage phase unbalance should be less than ± 3%
※9 Maximum value within the range of unit specifications.
※10 The figure noted is when the equipment is operating at the highest capacity of its normal operating range.
※11 Noise level can be decreased by installing a noise reducing duct.
Specifications
Water Cooled
※1 The temperature and humidity control ranges noted do not necessarily indicate the actual controllable ranges possible. The actual controllable temperature and humidity ranges will depend on the temperature and humidity of the intake air. (Vapor humidification is used in the humidity setting range of 65 ~ 75%.)
※2 Values indicated are for when the intake air temperature and humidity, and supply water temperature and supply water flow rate are stable. Noted accuracy is based on measurement by the internal controller at a single air outlet point.
※3 The noted external static pressure is when the controlled air is regulated at the outlet to produce the maximum rated processing air flow.
※4 Height includes outlet port.
※5 The HEPA filter box is shipped in a separate package from the main unit and must be installed on-site
※6 When processing at the maximum air flow and at the highest cooling capacity, the difference between the cooling water inlet and outlet ports is 6.5℃
※7 The figure noted is when the equipment is operating at the highest level of humidification.
※8 Supply compressed air that has been cleaned through filter and/or other processing. The cleanliness of the compressed air supply should match the air cleanliness standard of the target area to which the controlled air will be supplied.
※9 Source voltage phase unbalance should be less than ±3%
※10 Maximum value within the range of unit specifications.
※11 The figure noted is when the equipment is operating at the highest capacity of its normal operating range.
※12 The noise level may be lowered by installing noise-absorbing ducting.